23.3 Device Monitor and Management Interface in Express

WebAccess Express has a pre-built monitoring graphical Device Monitor and Management Interface. Users can save the time of the drawing and configure the information page and use the default pages to monitor and manage the device directly. The WebAccess Express View pages show the Device Overview and Device Status and set the Device Detail information, E-mail, and Alarm Value for building the Device Monitor and Management System.

 

 

Device OverviewThe main page of the device monitor interface. WebAccess Express now supports ADAM 2000/4000/6000 series, DiagAnywhere driver, SNMP driver, and EKI series. The overview page provides the entire information for six types of device.

Figure 24.4.3.1: WebAccess Express Display Page – Device Overview

 

1.      Overview StatusThe total amount of connected and disconnected devices  in the WebAccess Express Project

2.      Devices StatusThe total amount of devices based on each type of connected and disconnected devices. Users can click the number in the icon to monitor the information of the connected devices.

3.      Function bar of the projectUsers can change the page with the function button to display the device detail data, datalog trend, and Email setting page.

 

Real-Time MonitoringDisplay the real-time data of each of the online devices

Figure 24.4.3.2: WebAccess Express Display Page – Real-Time Monitor

 

 

ADAM Device display pageMonitor the ADAM module data of the ADAM2000/4000/6000 series the project support.

Figure 24.4.3.3: WebAccess Express Display Page – ADAM Device

 

1.        Face PlateShow the information of I/O Modules, including Device name, IP and I/O status.

2.            Device StatusThe icon shows the device situation. is online /  is offline /  is an Alarm . The icon will change to Alarm as more than one tag has an alarm.

Figure 24.4.3.4: WebAccess Express Display Page –Device Alarm Status

3.            Device Information Setting buttonPush the button to maintain the device information.

 

Figure 24.4.3.5: WebAccess Express Display Page –ADAM Device Information

 

 

Device Information SettingUsers can maintain the Device information and change the default settings via this page directly as the device maintenance management system. After changing, WebAccess will automatically save the information in the database.

    Figure 24.4.3.6: WebAccess Express Display Page – Device Information Setting

1.          Device Name & Block NameShows the device name and the block name in WebAccess.

2.          Device Detail InformationUsers can type the device information, i.e. Description, Device Owner, Device Warranty Info, and Device version to maintain the device.

3.          Tag InformationChange the Tag information, including Tag Name, Tag Description, and Alarm Priority of Tag status. The default page will show the default Tag and Description information built in the WebAccess block .The default High/Low Alarm setting value is the value which adds a 1% High/Low span.

 

 

TPC/UNO/PPC Platform health check pageDiagnose the Platform situation via the DiagAnywhere driver to check the health of the CPU, memory, temperature, and voltage of the target machine via this display.

Figure 24.4.3.7: WebAccess Express Display Page – Platform Diagnose

 

1.          Face plateShows the information of any Platform which has DiagAnywhere Driver installed. It includes the device name, IP and platform status.

2.          Platform StatusThe icon shows the device situation. is online /  is offline /  is Alarm. The icon will change to Alarm status when more than one tag is issuing an alarm .

3.          Function buttons

Figure 24.4.3.8: WebAccess Express Display Page –Time Synchronization

Figure 24.4.3.9: WebAccess Express Display Page –Time Synchronization window

 

Figure 24.4.3.10: DiagAnywhere Diagnosis page

Figure 24.4.3.11: Screen Snapshot Option

Figure 24.4.3.12: File Transfer Option

Figure 24.4.3.13: TPC/PPC/UNO Device Information Setting

 

IPC Platform health check pageDiagnose the Platform situation via the DiagAnywhere driver to check the health of the CPU, memory, temperature, and voltage of the target machine via this display.

Figure 24.4.3.11: WebAccess Express Display Page – Platform Diagnose

 

1.          Face plateShows the information of any Platform which has DiagAnywhere Driver installed. It includes the device name, IP and platform status.

2.          Platform StatusThe icon shows the device situation. is online /  is offline /  is Alarm. The icon will change to Alarm status when more than one tag is issuing an alarm .

3.          Function buttons Device Information Setting buttonPush the button and go to maintain the device detail information.IPC Platform health check pageDiagnose the Platform situation via the DiagAnywhere driver to check the health of the CPU, memory, temperature, and voltage of the target machine via this display.

 

 

 

EKI Device display pageMonitor the Advantech EKI devices situation via SNMP driver. The project support EKI Switch/Wireless/Device series.

Figure 24.4.3.14: WebAccess Express Display Page –EKI Device

 

1.          Face plateShow the information of EKI Modules, including Device name, IP, System Uptime, Firmware Version, and Port/Wireless Status.

2.          Device StatusThe icon shows the device situation. is online /  is offline /  is  Alarm status. The icon will change to Alarm status when more than one tag is in alarm value.

3.          Function buttons

Figure 24.4.3.15: EKI Setting Page Connection

Figure 24.4.3.16: EKI Setting Main Page

Figure 24.4.3.17: EKI Setting Page

Figure 24.4.3.18: EKI Device Information Setting

 

 

SNMP Device display pageMonitor the platform or device that supports SNMP driver. Users can monitor the information from SNMP mib file in WebAccess Express display.

Figure 24.4.3.19: WebAccess Express Display Page –SNMP Device

 

1.          Face plateShows the information of devices that support SNMP , including Device name, IP, System Uptime, and Description that have the same details as in the SNMP public mib description column.

2.          Device StatusThe icon shows the device situation. is online /  is offline /  is Alarm status. The icon will change to Alarm status as more than one tag is in alarm value.

3.          Device Information Setting buttonPush the button to maintain the device information.

Figure 24.4.3.20: SNMP Device Information Setting

 

 

Datalog TrendPush the Datalog Trend button, users can select the trend of device and go to Trend Analysis page.

Figure 24.4.3.21: Function button - Datalog Trend

 

Figure 24.4.3.22: Datalog Trend List

Figure 24.4.3.23: Datalog Trend page

About E-mail setting, please refer 6.2 Data Log Trend

 

 

E-mail SettingUsers can set the e-mail information in the project page directly for sending the alarm messages to the manager.

Figure 24.4.3.24: E-mail Setting page

 

About E-mail setting, please refer 3.2.8   Outgoing Email Server - SMTP